TONTOSTUDIO / MODULAR SYNTHESIS
AUDIO OFF—

Pitch, triggers and connectors adapt automatically.

Live signal

AUDIO OFF
OUTPUT · MONITORMIC
OUTPUT−∞ dBFS
MIC−∞ dBFS

Output follows the master level. Mic shows the preamp signal. Display gain only enlarges the traces.

Cable inspector 0 PATCHES

Normal connections stay active until a cable replaces them. Click a connected input to unplug it.

→

Performance

A W S E D F T G Y H U J K · COMPUTER KEYS
OCT 0
SEMITONES

Tape machine VARISPEED / TWO STEMS / EIGHT TAKES

0 TAKES
STOPPED00:00.00
No recordings yet.Record the cabinet mix and microphone as separate stems. Save a session or export takes before closing this page.
Choose a patch, start audio, and play a key.
TONTO STUDIO / FIELD GUIDE

Playing and patching TONTO

Start here

Choose a patch, click Start audio and play the keyboard. A W S E D F T G Y H U J K play notes; Z and X change octaves. Each cabinet has a level fader. The cabinets are monophonic; several cabinets can sound together.

Live signal

The orange trace shows the output after the master level, including tape playback and the monitor metronome. The green trace shows microphone audio after the preamp. Both use the same time window. Window changes the time scale; Display gain enlarges the traces without changing audio or the peak meters. Dock keeps the display visible while you scroll through the cabinets.

Patch a cable

Click or drag from an output to any green-ringed input. You can begin at either end. One output can feed several inputs. Escape cancels a loose cable. Click a connected input to restore its normal signal. The cable inspector also lets you connect ports by name.

Microphone and MIDI

Enable mic, then use Patch microphone or MIC OUT. Any input accepts the microphone signal. Use MIC ENV to control envelopes or gates with your voice's loudness. Set the destination's gain or modulation amount to hear the result. Use headphones while monitoring. MIDI note, velocity, pitch bend, sustain, CC1/11 expression and CC7 master level are supported.

Modern and historical modes

Modern mode converts pitch scales, trigger polarity and connector types. It preserves continuous pitch bends; it does not quantize. Historical mode keeps raw voltage. Cables with mismatched connectors remain open until you fit an adapter in the inspector. Add a pitch scaler or trigger converter when needed. Bond banana-connected cabinets using their GROUND switches to remove simulated hum. Normal connections include the appropriate internal conversions in both modes.

A 1.2 V/octave source into a 1 V/octave input stretches an octave to 14.4 semitones; the reverse compresses it to 10. The manual scaler also accepts negative gain and a DC offset. Its output is untyped CV, so its voltage is not scaled a second time.

Sequencer and utilities

Load patch 11, 12 or 13 and start audio. The three rows run together: A sets pitch in semitones; B and C output volts for timbre or loudness. Play sends a gate, Rest keeps the voltage but removes the gate, and Skip removes that step. Length and direction change the pattern. Keyboard transposes A lets keys shift its pitch. On small screens, scroll the rows sideways to reach all eight steps.

Patch Row A to an oscillator pitch input and Sequence gate to its envelope trigger. Clock pulse runs through rests; its ÷2, ÷4 and ÷8 outputs can drive slower parts. An external cable to Sequence clock replaces the tempo clock: Start arms it, and each rising edge advances. External gate duration follows the incoming pulse. Reset also resets the divider and switch. Step advances once and can audition a stopped sequence.

The three-way switch normally selects A, B and C, advancing on Clock ÷2. Replace its inputs with audio or other CV. The signed mixer combines three signals; a negative gain inverts one. Both VCAs normally follow the extra rise/fall function, which is triggered by Sequence gate. Patch their signal inputs to hear them. Quantizer normally takes Row A; Slew follows the quantizer. Slew times specify seconds per volt. Connect any utility output to a cabinet input to hear its effect.

The Moog 960, ARP 1601 and Buchla 245 used voltage sequencing; these controls combine useful period functions with modern conveniences, rather than duplicate one historical panel. Noise, sample-and-hold, ring modulation, lag and envelope following are also available in the existing ARP cabinet.

Spectral studio

Try patches 15–18. Filter audio normally receives the Moog voice; fourteen faders shape its low, high and twelve middle bands. The separate multimode filter exposes low-pass, band-pass and high-pass outputs together. Cutoff CV is one volt per octave.

For the vocoder, load Microphone vocoder, enable mic and speak. Play keys to change carrier pitch. The microphone controls twelve envelopes that shape a Moog saw carrier; their meters show the active bands. Patch any audio source into Modulator or Carrier. Sensitivity and Release set the response; Formant shift moves the carrier filter frequencies. Monitor chooses the cabinet output; the individual jacks are always available.

EMS matrix

Rows are sources and columns are destinations. Click a pin to connect; click again to remove it. Choose full, half or inverted strength before placing a pin. Several rows can feed a column. A cable to an EMS input overrides that matrix column. Drag the joystick or use its arrow keys.

Notes & motion

Use the Notes & motion link above the rack. Choose one, two, four or eight bars, set the tempo, and click Record loop. The count-in gives you time to reach the keys; Dock keys keeps them visible. Play from the screen, computer keyboard or MIDI controller and move synth controls. Recording ends at the bar boundary. Repeat plays the phrase continuously; turn it off for one pass. Notes follow the shared keyboard bus, so cabinets keep their mono or duo behavior.

Edit notes & automation opens the note list. Change pitch, start beat, duration and velocity; add or remove notes, quantize to a grid, or remove an automation lane. The overview shows pitch against time. Control movements play back as recorded; master volume, tempo and mains remain outside automation. Tempo stays fixed during playback or capture. The metronome goes to your monitor but never the tape stems. Tape Record captures the resulting synth audio, including automation. The performance loop records notes and controls; use Tape for microphone audio.

Factory sound patches keep the phrase so you can audition another sound. Phrase presets replace it with their included notes and motion. Saved patches, imports and sessions restore their own phrase. Save or export completes an active capture. Record loop replaces the current phrase; Undo recovers it. Patch JSON and session files include the loop. Audio recordings still require a session or WAV.

MIDI learn and undo

Open MIDI controller mappings below the loop. Choose a control, click Learn, and move a hardware knob. You can also right-click a synth control to select it. The next matching controller movement changes the control. Mappings are specific to device, channel and CC, and stay in this browser. Sustain and panic messages cannot be reassigned. Ordinary absolute MIDI CC values are supported; relative encoders need absolute mode.

Undo and Redo beside Patch memory restore controls, cables, matrix, sequencer edits and performance data. Ctrl/Command Z undoes; Ctrl/Command Shift Z or Ctrl Y redoes. Text and number fields keep native text undo. Restoring an edit stops notes and sequencers; tape takes are kept. The history contains the last forty edits, groups nearby control movements, and clears when you reload.

Patch library

Browse library searches patches by sound, instrument and technique. Filter by category or play mode, keep favorites, and preview sounds without changing your patch. Microphone previews use a generated test signal. Load patch applies the selected settings. Save current patch adds a memory with tags and notes; Edit name & notes changes a saved memory. Download bank exports your patches, favorites or search results. Import bank adds memories and numbers duplicate names. Banks contain settings, not tape recordings.

Performance presets include notes and control movements. Loading one replaces the current phrase; press Play loop to hear it. Other factory sounds keep your existing phrase. TONTO can also import 2600 Studio banks.

Patch memory and tape

Save stores controls, connections, adapter settings, ground bonds, sequence and matrix in this browser. Export makes a portable JSON file. Import also accepts patches from 2600 Studio. Audio stays on your computer. Tape records a stereo cabinet mix and a separate preamplified microphone stem, with eight three-minute takes, varispeed, reverse, layers and WAV export. Automatic recovery stores recordings locally and restores them after a reload. Save session downloads the patch, tape settings and full-resolution recordings as a portable backup. Open session restores that file in this studio. Patch JSON alone does not include audio.

What is modeled

The ARP cabinet runs the existing 2600 Studio DSP with its full patch surface. The other cabinets use original browser DSP: band-limited oscillators and a nonlinear ladder; an FM oscillator, wavefolder and vactrol-style low-pass gate; a three-pole diode-style filter and trapezoid; and macro voices, a delay resonator and overlapping grains.

These are playable approximations, not measured component-level replicas. The Eurorack modules are not Plaits, Clouds or Rings ports. The electrical model uses nominal impedances, pitch standards, trigger thresholds and optional synthetic hum. It does not predict the behavior or safety of physical hardware. Live audio requests 48 kHz; the display reports the audio context rate, and the browser converts to the device when needed. Higher rates remain available for offline reference renders; oscillator oversampling is internal to the Moog and ARP models. Named historical patches describe techniques, not exact recording reconstructions. No manufacturer affiliation.

Source and implementation notes ↗

Session and performance

Automatic recovery restores this browser’s last patch, clips and recordings with audio stopped. Play together starts clips and tape on the shared clock. Instrument parts provides MIDI channels, clip banks and chains. Clip editor adds draggable notes and automation curves. Tape edits include trim, fades and 24-bit or 32-bit float WAV export. Calibration profiles apply measured corrections; hardware equivalence remains unverified.

Device setup and measurement

Open Keyboard, microphone & output to choose a MIDI input and channel, check key and wheel messages, select a microphone, or change the monitor output where your browser supports it. Device choices stay in this browser, separate from patches. Export device check saves the activity and device details without audio. For oscillator calibration, measure at least three documented pitches across an octave, then Fit tuning & tracking. Enable Apply profile to use the result.